Product Name Decription Details

HLxxWIN Datalogger Support Software:
a. Program Editor
b. Real Time Monitor Mode
c. Terminal emulator
d. Auto-polling for multiple remote stations
e. Communication supports
f. Simple operation mode

TERM8W Datalogger Support Software:
a. Windows® Graphic Interface
b. Charts, Graphs and Reports
c. Wind Rose Charts
d. Database Editor
e. Program Editor
f. Auto Polling - Unlimited Remote Sites
g. Real Time Data Values and Real Time Gauges Display
h. Foreign languages


HLxx Light Datalogger Support Software: a. Program Editor
b. Real Time Monitor Mode
c. Terminal emulator
d. On-line new & history data view
e. Communication supports
f. Simple operation mode

HL20 Data acquisition system: a. 20 single-ended or 8 differential analog input channels
b. Expandable to more than 200 channels
c. 4 excitation voltage outputs
d. 4 pulse input channels
e. 6 digital control outputs
f. Low power consumption
g. Optional EEDSU data storage unit

HL20-A Data acquisition system: a. 20 single-ended or 8 differential analog input channels
b. Expandable to more than 200 channels
c. 4 excitation voltage outputs
d. 4 pulse input channels
e. 6 digital control outputs
f. Low power consumption
g. Optional EEDSU data storage unit

EEDSU Data Storage Unit a. Data storage capacity : > 350,000,000 data points
b. Power requirements : 12VDC ( 7 to 30 VDC )
c. Power consumption : < 15mA ( @12.6VDC ) in average.
d. Baud rate : Data transfer is 9,600 baud.
e. Temperature operating range : -25℃to +70℃
f. Dimension : 6.7cm * 6.7cm * 2.8cm

CEM416A Channel expansion module: a. 48 single-ended or 32 differential input channels
b. 16 full bridge input channels

VWA-1 VW to Analog Converter
a. Frequency range: 400 – 6000 HZ
b. Resolution: 24 bits
c. Response time: @ 0.5S ( @ 500mS ) after power-on
d. VW to Analog channel no.: 1 channel (VW)
e. Analog output: 0 – 2 VDC (VW)
f. Power requirement: 9 – 15 VDC
g. Dimension: @ 16 cm (L) x 6 cm (W ) x 2.7 cm (H)

HP2 Power Switch Module:
a. Channel number: 2
b. Control principle: none-contact switch
c. Control voltage: High: 5 VDC, Low: 0 VDC
d. Input power: 12 VDC ( < 50 VDC )
e. Output power: 12 VDC
f. Current drain: < 0.05 mA
g. Nominal load: < 1.5 A @12VDC

VS7 Logger & sensor series : a. 5 analog input channels
b. 2 potentiometer input channels
c. 3 pulse input channels
d. 2 continuous 5V & 12V power outputs
e. 16 characters by 2 line LCD display w/3 buttons
f. Adjustable logging interval from 1s up to 10+ hrs
g. 2 gigabyte data storage ( SD Card )

EE-04 Wind Sensor a. Measuring range:Wind speed: 0 - 75 m/s
Wind direction: 0 - 360 °
b. Accuracy: Wind speed: ±1 m/s( 0-20m/s )
±5% ( >20m/s )
Wind direction: ±7 °
c. Signal output: Wind speed: magnetically switch
Wind direction: potentiometer

03002 Wind Sentry Anemometer and Vane:
a. Measuring range: Wind speed: 0 – 50 m/s
Wind direction: 0 – 360 °
b. Accuracy: Wind speed: ± 0.5 m/s
Wind direction: ± 5 °
c. Signal output: Wind speed: magnetically induced AC voltage
Wind direction: potentiometer
d. Options: 03002V WS&WD: 0 – 1 VDC outputs
03102V WS: 0 – 1 VDC output
03302V WD: 0 – 1 VDC output

05103 Wind monitor: a. Measuring range: Wind speed : 0 - 100 m / s
Wind direction : 0 - 360°
b. Accuracy: Wind speed : ± 0.3 m / s or 1% of reading
Wind direction : ± 3°
c. Signal output: Wind speed : magnetically induced AC voltage
Wind direction : DC voltage - potentiometer
d. Options : 05103V with 0 - 5 VDC outputs
05103L with 4 - 20 mA outputs

MP101A Temp. / RH probe:
a. Measuring range:
Temperature : -40℃ - +60℃
Humidity : 0 - 100%
b. Accuracy:
Temperature : ± 0.3℃
Humidity : ± 1.5% ( 10 - 95% )
± 2.5% ( <10% or > 95% )

111N&222N Temp./RH probes:
a. Measuring range:
Temperature: -40 ℃ to + 60 ℃
Humidity: 0 - 100 %
b. Accuracy:
Temperature: ± 0.3 ℃ (-20 ℃ to + 40 ℃ )
± 0.5 ℃ (-40 ℃ to + 60 ℃ )
Humidity: ± 3 % (0 - 90 %)
± 5 % (90 - 98 %)

TH-46 Temp./RH probe: a. Measuring range:
Temperature: -40 ℃ to + 60 ℃
Humidity: 0 - 100 % RH
b. Accuracy:
Temperature: ± 0.15 ℃
Humidity: ± 1.0 % RH

888 & 884 Solar radiation shields:
a. Material: UV stabilized white thermoplastic plates
b. Principle: Natural ventilation
c. No power required
d. 888: 8 plates
e. 884: 4 plates

E20 Sillicon pyranometer: a. Spectral range: 400 - 1100 nm
b. Sensitivity: 48 uV / W / m2
c. Linearity: 1% up to 3000 W / m2
d. Accuracy: ± 3 %
e. Response time: typical 3 uS

LP02 Pyranometer: a. Spectral response: 305 - 2800 nm
b. Sensitivity: 10 - 40 uV/ W/ m2
c. Non - stability: < 1% change per year
d. Non -Linearity: ± 2.5 %
e. Response time 95 % : 18 Sec
f. Temperature range: -40 ℃ to + 80 ℃

SR11 First Class Pyranometer a. ISO classification: First Class
b. Spectral response: 305 – 2800 nm
c. Sensitivity ( nominal ): 15 uV/W/m2
d. Range: 0 – 2000 W/m2
e. Temperature dependence: < 0.1%/℃
f. Temperature range: -40℃ to +80℃
g. Calibration traceability: WRR


NR01 & RA01 Net Radiation – Pyrgeometer sensors
NR01 & RA01 Specs:
General:
a. Temperature range: -40℃ to +80℃
b. Range: 0 – 2000 W/m2
c. Temperature sensor: Thermister
d. Temperature sensor: users own preference can be plugged in
Pyranometer ( Short Wave ):
a. Pyranometer ISO classification: Second Class
b. Spectral response: 305 - 2800 nm
c. Calibration traceability: WRR
Pyrgeometer ( Long Wave ):
a. Spectral response: 4500 – 50000 nm
b. Calibration traceability: NIST
c. Window heating offset @ 1000 W/m2 solar radiation: < 15 W/m2
d. Heating power: 5 Watt @ 12VDC

MS-020VM Pyranometer: a.Spectral response: 400 – 1100 nm
b.Signal output: 0 – 1 VDC
c.Measuring range: 0 – 1400 W/ ㎡
d.Accuracy: < 4%
e.Response time: < 50 ms
f.Power supply: 12 – 24 VDC/7mA

BP0611A Barometric Pressure sensor: a.Measuring range:630 – 1130 mBar or hPa ( 18.6 – 33.4in. Hg ).
b.Resolution: Infinite.
c.Operating Temp.:-40ºC to + 85ºC.
d.Temp. Compensatedrange: 0ºC to + 70ºC.
e. Accuracy: ±0.125% FS
f.Power requirement:10 – 24VDC.
g. Current Consumption: Active 5mA @12VDC
                                             Static 1.1mA @12VDC.
h.Signal output: 0 - 2 VDC.

E90 Quantum sensor: a. Spectral range:  400 - 700 nm
b. Sensitivity:  2.7mV  per 1000 umols-1m-2
c. Linearity:  1 %  up  to  10,000 umols-1m-2
d. Accuracy:  ± 4 %
e.Stability: < ± 2 %  change over a 1 year period
f. Response time: typical 1 uS